      Data Center Map

      Somerset NJ III


      » Index » USA » New Jersey » New Brunswick » Somerset NJ III

      Somerset NJ III is located in the area New Brunswick, USA (America), and the colocation data center is not carrier neutral. The data center was last updated on 27-05-2010.


      Address:
      Datapipe, Inc.
      125 Belmont Dr
      08873 Somerset
      New Jersey, USA

      » Request quote
      » Visit website

      Click here to find other data centers
      owned and operated by Datapipe, Inc..


      Profile
      Tenants
      Request quote
      Office space
      Rack Cabinets
      Dedicated Servers
      Suites
      Footprints
      Virtual Servers
      Cages
      Hosting of individual servers
      Remote Hands

      Profile


      Purpose Built Design
      . Tier III Standard Compliant - Certification Pending
      . PCI Level 1 Service Provider Certified
      . SAS 70 Type II certified, HIPAA Compliant
      . 56,600 square foot facility
      . Direct connectivity to Datapipe network
      . VESDA smoke detection systems, above and below raised floor
      . Advanced multi-zone, double pre-action, dry pipe-fire suppression system
      . Fully redundant building and security management systems

      Network
      . Direct connectivity to Datapipe network available
      . Carrier Neutral Facility with multiple Tier 1 providers
      . Dedicated Dark Fiber Ring with diverse paths and full redundancy
      . Direct Fiber connectivity to primary New York City POP
      . Network fully supports Fibre channel, SONET & Ethernet handoffs

      HVAC Temperature Controlled Environment
      . Liebert CRAC units - N+2 implementation
      . Temperature range of 72 +- 5 degrees Fahrenheit
      . Relative humidity range from 40% - 60% RH
      . Hot / cold isles with hot isle containment
      . Raised floor cold Plenum supply, ceiling warm return plenum to provide uniform cooling distribution Security
      . Three factor security
      . 24/7 facility and network monitoring
      . 24/7 security staff, strictly enforced security procedures
      . Visitors are escorted by authorized personnel at all times
      . 24 hour internal and external video surveillance, 90 day minimum retention policy
      . Multiple mantraps with reinforced walls

      Power Conditioning
      . Facility fed by redundant 13.2Kv feeds N+N design
      . N+N Backup Generator Infrastructure
      . Two Contracted fuel suppliers on call 24/7
      . Minimum 150kw per square foot
      . Dual A+B circuit feeds to each rack - 30AMP 208VAC N+N implementation
      . Fully redundant Eaton Powerware UPS Systems - N+N implementation


      Somerset NJ III Pricing/Quotes


      If you are interested in receiving a quote for Datapipe, Inc., please try our free quote service.

      Copyright © Data Center Map - Sitemap
      Your guide to colocation data centers, managed hosting, cloud servers etc.
      av 国产 日韩 欧美 在线播放
      <big id="5brt0"><em id="5brt0"></em></big>
    1. <object id="5brt0"></object>
    2. <code id="5brt0"></code><code id="5brt0"></code>
    3. <th id="5brt0"><sup id="5brt0"></sup></th><pre id="5brt0"></pre>

      <code id="5brt0"></code>