      AdNet - DataCity Bucharest


      » Index » Romania » Bucharest » AdNet - DataCity Bucharest

      AdNet - DataCity Bucharest is located in the area Bucharest, Romania, and the colocation data center is carrier neutral. The data center was last updated on 04-07-2017.


      Address:
      AdNet Telecom
      Blv. Pipera, Nr.1/VI
      077190 Voluntari
      Ilfov, Romania

      » Request quote
      » Visit website

      Click here to find other data centers
      owned and operated by AdNet Telecom.


      Profile
      Gallery
      Tenants
      Connectivity
      Request quote
      Office space
      Rack Cabinets
      Dedicated Servers
      Suites
      Footprints
      Virtual Servers
      Cages
      Hosting of individual servers
      Remote Hands

      Profile


      TIER III DESIGN:
      Availability higher than 99.982%
      Redundant power elements with independent
      circuits paths configured in as 1+1
      Redundant cooling elements with
      independent circuits paths configured in as N+1
      Provides concurrent maintenance

      ENERGY EFFICIENT:
      Optimized IT Equipment arrangement in Cold/Hot Aisle
      Advanced multistep cooling control allow for high efficiency
      Integration of green energy such as photovoltaic and wind turbine
      High performance rectifiers, inverters and accumulators in UPS system
      Targeted PUE - Power usage effectiveness lower than 1.3 for 100% load
      Actual PUE - 1.75 at 20% Load

      IT & TELECOM INFRASTRUCTURE:
      IT infrastructure design for TIER III
      Multipath optical fiber on 3 circuits
      High end border routing equipment Juniper MX series
      Data Center L2 and L3 switching performed by Cisco Nexus
      Complex evolved virtualization platform based on Cisco UCS, HP 3PAR
      storage and VMWare VCenter/Vsphere
      Cluster balancing technology from A10 Networks
      Advanced traffic anomaly detection and cleaning with Arbor System technology
      Complete internal data circuits distribution with Panduit materials

      COOLING:
      Adiabatic & Free cooling - Indoor for IT Containers:
      60 racks with average power of 7 KW arranged in 3 cold aisle with 20 racks each resulting in a total power of 140KW / cold aisle
      24 LCU providing 20KW of cooling arranged in 3 cold aisle resulting in 8 units / row with a capacity of cooling of 160KW (7+1)
      In-line positioning with racks, Cold-Isle/Hot Isle containment with front to back airflow
      Cooling agent: thermic agent with heat transfer properties optimized for whole range of meteorological conditions
      Chiller water cooling - Outdoor:
      3 x 300KW chiller units with Free Cooling mechanism
      "Air-Conditioning" type water cooling - compressors based in 12 steps (4 independent compressors / chiller unit)
      N+1 Redundant compressors, ventilators and other components (according to TIER III standards for cooling)
      Automation system for adjusting electrical energy consumption
      Adiabatic & Free cooling - Indoor for Power containers
      4 units 30KW
      N+1 redundancy type according to TIER III standards for power supply

      POWER & UPS:
      Total installed power 480 kW x 2 with redundancy in 2 lines
      2 automatic back-up diesel generators one for each line
      Accumulators pack - 108 with 100 Ah capacity for each power box
      2 UPS of 40 kVA for chiller pumps
      2 UPS of 20 kVA for interior modules of inline cooling units
      2 heating pumps and 1 ice pillar for extra heat removal before Chillers
      1 wind turbine with 2 KW - providing auxiliary power
      80 x 250W (20 KW) photovoltaic farm - compensating in extra hot summer days

      RACKING & VIRTUALIZATION:
      Racks
      Hardened steel Racks:
      45U racks space proving at least 42U usable IT Equipment
      Depth: 1000mm
      Width: standard 19''
      PDU: for each Rack 2 PDU three-phase power supply of 400V - Maximum power 11 KW redundant/ Rack, each PDU with 24 IEC13 sockets and 6 IEC19 sockets
      Assembling on metallic anti vibration and anti seismic system

      Virtualization system
      Cisco UCS Blade Server System
      5 x Blade server chassis each with 8 blade server units installed
      Installed processing power ~ 1800 VCPU
      Installed memory : 7168 GB
      HP 3PAR 7400 Enterprise Storage Dual controller with 200TB of usable space (250TB installed)
      Storage: even mix of SAS/NL-SAS disk
      Switching: Integrated Cisco switch fabric with extra 32 port 10GB for external connectivity
      VMWare VSphere/VCenter Enterprise plus virtualization system

      SECURITY SYSTEM:
      Complex security system
      Fire detection system
      Smoke detection sensor
      Temperature sensor
      Fire extinguisher cylinders
      Fire detection station
      Exterior fire alarm control panel from fast access from outside
      Dual power source, both from main power supply and UPS
      Access control module
      Emergency fire path - both mechanical and electromagnetic
      Magnetic stripe card access
      Unlimited user access with multiple roles and rights
      Control panel integration with fire detection and extinguisher system - automatic fire path unlocking
      Real time reports and history : access type, users, access path, etc.
      Surveillance system
      HD IP cameras
      NVR recording and monitoring
      Minimum 30 days data storage in

      INFRASTRUCTURE MANAGEMENT:
      Complex monitoring and management software suite integrating all hardware and software components installed in the datacenter infrastructure (power elements, cooling elements, security & surveillance, sensors & monitoring devices)
      Data center components detailed charts and schematics (racks, cooling, power, surveillance, control access, sensors, etc.)
      IT Equipment layout
      Power supply, circuits and distribution
      Chillers, LCU, cooling paths
      Surveillance, access control, firefighting systems
      Humidity, temperature, air quality, flood sensor system
      Renewable energy controllers
      Real time & Historical monitoring for all managed systems
      Statistics, Graphics and Analysis of various parameters
      Friendly graphical web user interface compatible with most modern browsers

      CONNECTIVITY:
      Physical connections (L1):
      3 paths geographically and logically independent underground optical fiber links - 144 optical wires available
      Open Third-party fiber optic interconnection cabinet easily accessible from any underground infrastructure
      Logical connections (L2-L3):
      Data center node is included in main N x 10Gbps metropolitan multi-ring core network of 2K Telecom, providing high capacity resilient communications with most POP or exchange nodes
      Juniper MPLS Switches and Routers provide any type of logical connection (L2 circuits, VPLS, L3 VPN, QinQ, Dark Fiber, TDM transport, etc.)
      External connections (National&Internet)
      2KTelecom is member of public Internet Exchanges: Interlan, Balkan-IX RoNIX, NxData, IBM Data Center, INES Datacenter, Cyberhost Datacenter
      Extra private national interconnection with leading ISP providers improve capacity and latency
      Optimized Balanced Access to Internet is achieved through major world wide Internet Carriers (M247/NTT, Telekom/LEVEL3)








      AdNet - DataCity Bucharest Pricing/Quotes


      If you are interested in receiving a quote for AdNet Telecom, please try our free quote service.

      Copyright © Data Center Map - Sitemap
      Your guide to colocation data centers, managed hosting, cloud servers etc.
      av 国产 日韩 欧美 在线播放
      <big id="5brt0"><em id="5brt0"></em></big>
    1. <object id="5brt0"></object>
    2. <code id="5brt0"></code><code id="5brt0"></code>
    3. <th id="5brt0"><sup id="5brt0"></sup></th><pre id="5brt0"></pre>

      <code id="5brt0"></code>