      Data Center Map

      544 Inspecteur


      » Index » Canada » Montreal » 544 Inspecteur

      544 Inspecteur is located in the area Montreal, Canada.
      The data center building was last updated on 06-06-2017.


      Address:
      Urbacon Data Centre Solutions
      544 Rue de L'Inspecteur
      H3C 2K9 Montreal
      ON, Canada

      Website:
      » Visit

      Click here to find other buildings
      owned and operated by Urbacon Data Centre Solutions.


      Profile
      Gallery
      Data Centers
      Connectivity
      NEXT GENERATION DATA CENTRE
      544 RUE DE L'INSPECTEUR, MONTREAL

      COMPUTER ROOM SPECIFICATIONS
      Available rooms 7 dedicated data floors plus 1 half floor on ground level each with standard critical power of 1.5MW or 2.0MW per data floor, and high density ready.

      Typical data floors provide 10,000 SF for IT equipment, ~20,000 GSF, and cabinet space 600 standard 24'W x 48"D or 370 standard 32"W x 48"D per data floor. Standard power density of 150 watts per square foot with optional density of 200 watts per square foot

      Structural slab to slab floor heights are 16'6" with loading of over 200 pounds per square foot.

      19,140 SF of office available for lease and ~5,000 SF storage available in basement level

      7x24x365 Security with check points for all access, ballistic glass and walls, electronic access with dual authentication and minimum 1 biometric reader. Video surveillance 7x24x365 of all exterior and interior areas, and minimum 30 days of archive.

      CRITICAL POWER
      Total megawatts 30 MW

      UPS SYSTEMS
      Description - High efficiency static UPS
      Redundancy - N+1 or 2N as required

      GENERATORS
      Description - 2.75 MW diesel generator
      Redundancy - N+1 or 2N as required

      ON SITE FUEL CAPACITY
      5 x 50,000 L + 1 x 30,000 L underground diesel storage
      24 hours minimum run time

      HEAT REJECTION SYSTEMS
      Distributed and N+1 redundant KyotoCooling systems dedicated per data floor.
      Annualized PUE of 1.2 or better unaffected by critical load utilization.

      PDUs
      250 amp overhead busway, optional multiple 400 KVA PDUs, 480V primary, 400/230V
      secondary available. 2N redundancy.

      COMMUNICATIONS
      2 separate network points of entry with diverse underground duct banks to local network
      Dedicated diverse conduits and risers to each data floor.
      Carrier neutral facility with multiple carriers.

      FIRE PROTECTION
      Double interlocked pre-action dry type sprinkler system with VESDA throughout building

      DESIGN PUE
      Montreal NGDC is designed to be best in class with an annualized PUE of 1.20 or better regardless of critical load utilization




      Search


      Search for more information about the company Urbacon Data Centre Solutions or the building 544 Inspecteur.



      Copyright © Data Center Map - Sitemap
      Your guide to colocation data centers, managed hosting, cloud servers etc.
      av 国产 日韩 欧美 在线播放
      <big id="5brt0"><em id="5brt0"></em></big>
    1. <object id="5brt0"></object>
    2. <code id="5brt0"></code><code id="5brt0"></code>
    3. <th id="5brt0"><sup id="5brt0"></sup></th><pre id="5brt0"></pre>

      <code id="5brt0"></code>